Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • The Profound UI installation was upgraded from a level prior to Version 5, Fix Pack 8.0 to a version after Version 5, Fix Pack 10.2.1
  • Database-driven widgets fail to show data after upgrading.
  • There is an error in the job log or network response: "Character conversion between CCSID 1208 and CCSID 65535 not valid."
  • Changing the view or display file is not reasonable.2

 


Example:

Code Block
javascript
javascript
pui["read db driven data as ebcdic"] = true;

...

1 This configuration option is available with versions after Profound UI Version 5, Fix Pack 10.1. Thus, if Profound UI was upgraded to fix pack Fix Pack levels 9.0, 9.1, 10.0, or 10.1 of Version 5, then Tech Support must provide a patch in order to use this option.

...